Low-e 코팅과 단열 스페이서 적용에 따른 알루미늄 및 PVC 프레임 복층 유리 창호시스템의 단열성능 평가



Low-e 코팅과 단열 스페이서 적용에 따른 알루미늄 및 PVC 프레임 복층 유리 창호시스템의 단열성능 평가

Insulation Performance Evaluation of the Aluminum and PVC FramedDouble Glazing Window Systems with Low-e Coating and Insulation Spacer
저자 송승영, 김수미, 박효순
소속 이화여자대학교, 한국에너지기술연구원, 이화여자대학교
학술지정보 대한건축학회논문집(계획계)
발행정보 대한건축학회 2006년
자료제공처 국회도서관 국립중앙도서관 NRF
주제분야 공학 > 건축공학
<초록>
This study aims to evaluate insulation performance of aluminum and PVC framed double glazing window systems with low-e coating and insulation spacer by the heat transfer simulation. To the aluminum and PVC framed double glazing window systems with and without low-e coating and insulation spacer, U-factors of each part and total window system were calculated for the evaluation of energy performance. Also temperature difference ratio was derived from the lowest inside surface temperature for the evaluation of inside surface condensation under the various conditions of inside air temperature, humidity and outside air temperature. The results show that the application of low-e coating and insulation spacer can substantially increase the energy performance and temperature difference ratio for preventing inside surface condensation, respectively.
This study aims to evaluate insulation performance of aluminum and PVC framed double glazing window systems with low-e coating and insulation spacer by the heat transfer simulation. To the aluminum and PVC framed double glazing window systems with and without low-e coating and insulation spacer, U-factors of each part and total window system were calculated for the evaluation of energy performance. Also temperature difference ratio was derived from the lowest inside surface temperature for the evaluation of inside surface condensation under the various conditions of inside air temperature, humidity and outside air temperature. The results show that the application of low-e coating and insulation spacer can substantially increase the energy performance and temperature difference ratio for preventing inside surface condensation, respectively.
<목차>
Low-e 코팅과 단열 스페이서 적용에 따른 알루미늄 및 PVC 프레임 복층 유리 창호시스템의 단열성능 평가 / 송승영 ; 김수미 ; 박효순 1
Abstract 1
1. 서론 1
2. Low-e 코팅 및 단열 스페이서 현황 2
3. 단열성능 평가 방법 2
4. 단열성능 평가 3
5. 결론 8
참고문헌 8









저희 (주)한국녹색인증원은 '지속가능한 저탄소 녹색건축인증 기술연구소'의 전문기업으로 설립되어, 빠른 제도 변화와 변모하는 건설환경에 이바지하고자 합니다. (주))한국녹색인증원은 건축, 도시, 생태분야가 녹색건축물에 접목될 수 있도록 적절한 요소분석을 통해 에너지 절감형 건축, 자생적 생태환경, 온열환경, 빛환경의 면밀한 조사와 연구로 고객의 삶의 질 향상 및 더 나아가 인류의 존속성에 그 목적을 두고 있습니다. 한국녹색인증원은 친환경컨설팅 전문업체로 주택성능등급, 그린홈, 에너지소비총량제, 에너지성능지표검토서, 건물에너지효율등급, 장수명주택