라벨이 #Condensation인 게시물 표시

공동주택 결로 하자 사례를 통한 개선방안 도출

이미지
공동주택 결로 하자 사례를 통한 개선방안 도출 Study on the Improvement Plans of Condensation Defect Examples in Apartment Building ​ 저자 오세민, 박선효, 정광섭 학술지정보 설비공학논문집 KCI 발행정보 대한설비공학회 2017년 피인용횟수 0 자료제공처 국회도서관 KISTI 기계·건설공학연구정보센터  주제분야 공학 > 기타공학  <초록> There are main issues of defect type that condensation, concrete crack and noise in apartment buildings. Especially, according to the Apartment Defect Dispute Mediation Committee in Korea (ADDMC) at Ministry of Land Infrastructure and Transport in Korea (MLIT), condensation defects are great importance (14 percent) on whole number of reported cases of faults from 2015 in Korea. Most condensation defects have many different causes that take a toll on the resident's life and space. So it is very important to early detection and repair. For preventing the condensation in apartment buildings, there are building codes in Korea such as 'Standard of Method and Judgment for Apartment defect of investigation, Repair cost Est

결로수 배출구 유무에 따른 삼중유리 시스템창의 결로방지성능 및 기밀성능 실험 평가

이미지
결로수 배출구 유무에 따른 삼중유리 시스템창의 결로방지성능 및 기밀성능 실험 평가 Condensation Resistance and Air-tightness Test Evaluations of Triple Glazing Windows with and without Drainage Holes 저자명 박시현, 김민희, 임재한, 송승영 문서유형 학술논문 학술지 한국건축친환경설비학회 논문집 10권 1호 (2016. 2) 발행정보 한국건축친환경설비학회 |2016년 |한국 |한국어 주제분야 공학 > 건축공학  서지링크 국회도서관 , 건축도시연구정보센터 <초록> The condensation risk for windows during winter is high, and such condensation can lead to mold problems, thereby causing discomfort for building occupants. Triple glazing window systems used for energy saving, consist drainage holes placed on glazing beads or gaskets providing a path for condensed water from inside to outside. These holes are considered to be effective in view of draining condensed water. However, these holes may lead to the decrease of air-tightness as well as the increase of condensation risk resulted from the drop of surface temperature due to the intake of cold outside air. Therefore, in this study, the triple glazing

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구

이미지
커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System 저자명 이선우 문서유형 학술논문 학술지 설비공학논문집 제29권 제1호 (2017년 1월) 21-28  발행정보 대한설비공학회 |2017년 |한국 |한국어 주제분야 공학 > 기타공학  서지링크 국회도서관 (청구기호 697.05 ㄱ364) , KISTI , 기계·건설공학연구정보센터 국회도서관 <초록> Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summe

커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구

이미지
커튼월의 단열 향상 및 결로 방지를 위한 통기구조 적용방안 연구 Application of Ventilated Cavity for Enhancing Insulation and Preventing Condensation of Curtain-wall System 저자명 이선우 문서유형 학술논문 학술지 설비공학논문집 제29권 제1호 (2017년 1월) 21-28  발행정보 대한설비공학회 |2017년 |한국 |한국어 주제분야 공학 > 기타공학  서지링크 국회도서관 (청구기호 697.05 ㄱ364) , KISTI , 기계·건설공학연구정보센터 국회도서관 <초록> Curtain-wall systems have been widely applied to buildings because of their lightweight and constructability characteristics. However, as curtain-wall systems include many building materials, vapor barriers can become damaged and condensation can occur. Due to the material properties of stone curtain-walls, the external appearance and structure of a building could be damaged and the insulating performance of the curtain-wall could be worse. Natural ventilation using an air cavity in a curtain-wall is expected to be effective for the prevention of condensation in inner walls and for the reduction of building cooling energy use in the summ