라벨이 #단열성인 게시물 표시

건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가

이미지
건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가 A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating 저자 장철용, 김치훈, 안병립, 홍원화 ​소속 한국에너지기술연구원, 경북대학교 건축공학과, 경북대학교 학술지정보 한국태양에너지학회논문집 KCI 발행정보 한국태양에너지학회 2010년 자료제공처 국회도서관 KISTI 기계·건설공학연구정보센터 건축도시연구정보센터 한국연구재단 주제분야 공학 >  기타공학 <초록> Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend. In addition, the building regulation U-value limitation of window is 3.3W/㎡․K in southern regions, while U-value limitation of wall is 0.35~0.58W/㎡․K. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment . The results of this study are as follows; 1) The insulation performance of super window system is 1.44 W/㎡℃ 2)Super Win