39층 철골건물의 진동사고 원인규명을 위한 현장계측



39층 철골건물의 진동사고 원인규명을 위한 현장계측


Field Measurements for Identification of the Vibration Accident Cause of a 39-Story Steel Building Structure
저자 이상현, 우성식, 정란, 이동근
소속 단국대학교, 단국대학교, 단국대학교, 성균관대학교
학술지정보 대한건축학회논문집(구조계)
발행정보 대한건축학회 2013년
자료제공처 국회도서관 한국연구재단
주제분야 공학 > 건축공학

<초록>
In this paper, the field vibration measurement tests and analysis have been conducted for investigating the exact causes of the abnormal vibration accident which occurred on last July 5 2011 in TechnoMart. The vertical accelerations of the building floors were measured under the 4D movie-theatre operation and human rhythmic movements in a fitness centre which were estimated as ones of the vibration sources. From field tests, it could be identified that the building has global vertical vibration mode of 2.7Hz natural frequency and human group rhythmic movements having frequency component mainly close to 2.7Hz in a fitness centre caused the resonance of the vertical mode. The peak acceleration caused by the taebo was 7 which is slightly higher than the ISO 2631-2;1989 serviceability standards of an office building.
<목차>
39층 철골건물의 진동사고 원인규명을 위한 현장계측 / 이상현 ; 우성식 ; 정란 ; 이동근 1
Abstract 1
1. 서론 1
2. 대상구조물 및 사고 개요 2
2.1. 대상구조물 개요 2
2.2. 사고 개요 및 추정진동원 2
3. 현장계측 2
3.1. 4D 상영관 3
3.2. 피트니스 센터 4
3.3. 피트니스 센터 진동시연 7
3.4. 연직방향 진동에 따른 사용성 및 감쇠비 평가 8
4. 결론 9



참고문헌 9







저희 (주)한국녹색인증원은 '지속가능한 저탄소 녹색건축인증 기술연구소'의 전문기업으로 설립되어, 빠른 제도 변화와 변모하는 건설환경에 이바지하고자 합니다. (주))한국녹색인증원은 건축, 도시, 생태분야가 녹색건축물에 접목될 수 있도록 적절한 요소분석을 통해 에너지 절감형 건축, 자생적 생태환경, 온열환경, 빛환경의 면밀한 조사와 연구로 고객의 삶의 질 향상 및 더 나아가 인류의 존속성에 그 목적을 두고 있습니다. 한국녹색인증원은 친환경컨설팅 전문업체로 주택성능등급, 그린홈, 에너지소비총량제, 에너지성능지표검토서, 건물에너지효율등급, 장수명주택

댓글

이 블로그의 인기 게시물

화재의 예방 및 안전관리에 관한 법률 시행규칙[시행 2022. 12. 1.]

지속가능한 기반시설 관리 기본법 시행령[시행 2022. 12. 8.]

발전소주변지역 지원에 관한 법률 시행령[시행 2023. 1. 12.]