동심 배관 내 결로 현상을 수반하는 공기유동 해석
동심 배관 내 결로 현상을 수반하는 공기유동 해석
Air Flow Analysis in a Coaxial Pipe Subject to Dew Condensation
저자명 (발표자명)이형식, 도기정, 이상호
문서유형 학술발표자료
학술행사 대한설비공학회 2006년도 동계학술발표대회 논문집
발행정보 대한설비공학회 |2006년 |한국 |한국어
주제분야 공학 > 공학일반
서지링크 KISTI , 국립중앙도서관 , 건축도시연구정보센터
<초록>
In this study, numerical modeling was performed to analyze wet air flow through a coaxial pipe subject to dew condensation for various outer surface temperatures of the inner pipe. The wet air was assumed to be of 20℃ and 80 % RH at constant velocity at inlet and the outer surface of coaxial pipe was considered to be under adiabatic condition. For 4 cases of inner pipe surface temperature ranging from 1℃ to 7℃, the distributions of flow parameters such as temperature, velocity and density were examined and compared. Also condensate mass fraction distributions for each case model were investigated and it was found that for the case of 7℃condition, the condensate mass fraction was about 0.0032 which is 2.4 times smaller than that of 1℃ condition.
In this study, numerical modeling was performed to analyze wet air flow through a coaxial pipe subject to dew condensation for various outer surface temperatures of the inner pipe. The wet air was assumed to be of 20℃ and 80 % RH at constant velocity at inlet and the outer surface of coaxial pipe was considered to be under adiabatic condition. For 4 cases of inner pipe surface temperature ranging from 1℃ to 7℃, the distributions of flow parameters such as temperature, velocity and density were examined and compared. Also condensate mass fraction distributions for each case model were investigated and it was found that for the case of 7℃condition, the condensate mass fraction was about 0.0032 which is 2.4 times smaller than that of 1℃ condition.
In this study, numerical modeling was performed to analyze wet air flow through a coaxial pipe subject to dew condensation for various outer surface temperatures of the inner pipe. The wet air was assumed to be of 20℃ and 80 % RH at constant velocity at inlet and the outer surface of coaxial pipe was considered to be under adiabatic condition. For 4 cases of inner pipe surface temperature ranging from 1℃ to 7℃, the distributions of flow parameters such as temperature, velocity and density were examined and compared. Also condensate mass fraction distributions for each case model were investigated and it was found that for the case of 7℃condition, the condensate mass fraction was about 0.0032 which is 2.4 times smaller than that of 1℃ condition.
<목차>
ABSTRACT
1. 서론
2. 본론
3. 결과 및 고찰
4. 결론
참고문헌
1. 서론
2. 본론
3. 결과 및 고찰
4. 결론
참고문헌
녹색건축인증 조성법' 및 '건물에너지 소비증명제'가 의무화되어 시행되고 있습니다.
저희 (주)한국녹색인증원은 '지속가능한 저탄소 녹색건축인증 기술연구소'의 전문기업으로 설립되어, 빠른 제도 변화와 변모하는 건설환경에 이바지하고자 합니다. (주))한국녹색인증원은 건축, 도시, 생태분야가 녹색건축물에 접목될 수 있도록 적절한 요소분석을 통해 에너지 절감형 건축, 자생적 생태환경, 온열환경, 빛환경의 면밀한 조사와 연구로 고객의 삶의 질 향상 및 더 나아가 인류의 존속성에 그 목적을 두고 있습니다. 한국녹색인증원은 친환경컨설팅 전문업체로 주택성능등급, 그린홈, 에너지소비총량제, 에너지성능지표검토서, 건물에너지효율등급, 장수명주택인증, CPTED, BF 인증 등 각종 친환경 건축물 인증 을 컨설팅 해드리고 있습니다. 녹색건축인증 의 선도기업이 되겠습니다.
댓글
댓글 쓰기